Tubulin (HiLyte 488TM dye labeled; porcine, micro-injctn)
货号 | TL488M-A | 售价(元) | 5271 |
规格 | 5 x 20 µg | CAS号 |
- 产品简介
- 相关产品
HiLyte Fluor™ 488 labeled microtubules formed from HiLyte Fluor™ 488 labeled tubulin.
Product Uses Include:
Laser based applications
Monitoring microtubule dynamcs in living cells
Speckle microscopy
Formation of fluorescent microtubules
Microscopy studies of MAP and microtubule associated motor activities
Nanotechnology
Material:
Porcine brain tubulin (>99% pure, see Cat. # T240) has been modified to contain covalently linked HiLyte Fluor™ 488 (HiLyte Fluor is a trademark of Anaspec Inc, CA) at random surface lysines. An activated ester of HiLyte Fluor™ 488 was used to label the protein. Labeling stoichiometry was determined by spectroscopic measurement of protein and dye concentrations (dye extinction coefficient when protein bound is 76,000M-1cm-1). Final labeling stoichiometry is 1-2 dyes per tubulin heterodimer. HiLyte Fluor™ 488 labeled tubulin can be detected using a filter set of 440-460 nm excitation and 500-520 emission. HiLyte Fluor™ 488 tubulin is in a versatile, stable and easily shipped format. It is ready for micro-injection or in vitro polymerization. Cytoskeleton, Inc. also offers AMCA (Cat. # TL440M), rhodamine (Cat. # TL590M), X-rhodamine (Cat. # TL620M) and HiLyte Fluor™ 647 (Cat. # TL670M) labeled tubulins of the same quality.
Purity:
The protein purity of the tubulin used for labeling is determined by scanning densitometry of Coomassie Blue stained protein on a 4-20% polyacrylamide gel. The protein used for TL488M is >99% pure tubulin (Figure 1 A). Labeled protein is run on an SDS gel and photographed under UV light. Any unincorporated HiLyte Fluor™ 488 dye would be visible in the dye front. No fluorescence is detected in the dye front, indicating that no free dye is present in the final product (Figure 1 B).
Figure 1: HiLyte Fluor™ 488 tubulin protein purity determination. A 50 µg sample of unlabeled tubulin protein was separated by electrophoresis in a 4-20% SDS-PAGE system and stained with Coomassie Blue (A). Protein quantitation was performed using the Precision Red Protein Assay Reagent (Cat. # ADV02). 20 µg of the same protein sample was run in a 4-20% SDS-PAGE system and photographed directly under UV illumination (B).
Biological Activity:
The biological activity of HiLyte Fluor™ 488 tubulin is assessed by a tubulin polymerization assay. To pass quality control, a 5 mg/ml solution of AMCA labeled tubulin in G-PEM plus 5% glycerol must polymerize to >85%. This is comparable to unlabeled tubulin under identical conditions.